Most buyers arriving with a superalloy density and weight question about 4J29 need one decision on superalloy density and weight, not a survey. The verified 4J29 data and the routing logic here close it for good.

4J29 is a Precision grade whose datasheet leans on one documented property: Thermal expansion matches borosilicate glass.

As a chemistry anchor from the verified composition tables, Inconel 718 spans Ni 50.0-55.0%, Cr 17.0-21.0%, Mo 2.80-3.30% and Nb 4.75-5.50%, and Hastelloy C-276 spans Mo 15.0-17.0%, Cr 14.5-16.5%, Fe 4.0-7.0% and W 3.0-4.5%.

What Superalloy Density and Weight means for 4J29

4J29 on superalloy density and weight: density 8.17 g/cm³, verified ceiling 450 °C. The deciding facts are temperature, media and form, and they land on glass-to-metal and ceramic-to-metal seals in electronic packages.

Property4J29
Grade4J29
Density8.17 g/cm³
Max service temp450 °C
Best dutyGlass-to-metal and ceramic-to-metal seals in electronic packages
Available formsWire, Strip, Bar & Rod, Plate & Sheet
StandardsASTM F15, GB/T 14986, MIL-I-23011

Specification signals

For 4J29, the verified density is 8.17 g/cm³. The documented applications tell the same story (transistor and ic hermetic packages, microwave tube windows), and a duty outside that list deserves a second look before 4J29 goes on the order.

  • The feature that separates 4J29 from its nearest neighbours is specific: Thermal expansion matches borosilicate glass. Hold the 4J29 certificate to proving it, not asserting it.

In practice

Multiply 8.17 g/cm³ by the section volume and the quote’s mass line stops being a surprise. Carry 8.17 g/cm³ into the budget and glass-to-metal and ceramic-to-metal seals in electronic packages gets weighed before it is ordered.

How to select the right option for your process

Run the list top to bottom before the enquiry goes out, that is what keeps the part inside its specification:

  1. Step 1: Confirm the maximum service temperature. Fix the peak continuous service temperature the component will see. It decides whether a precipitation-hardened grade such as Inconel 718 (rated 650 °C) or an oxidation-resistant solid-solution grade such as Hastelloy X (rated 1100 °C) is even in the running.
  2. Step 2: Match the environment and alloy family. Identify the corroding or oxidizing media (chlorides, acids, seawater, combustion gas) and match the family: Ni-Cr-Mo for wet corrosion, Ni-Cu for seawater and hydrofluoric acid, cobalt-base for wear and biocompatibility, precision grades for controlled physical properties.
  3. Step 3: Choose the product form. Select the semi-finished form: bar and rod (Ø6-350 mm), plate and sheet (0.5-80 mm), strip (0.05-3.0 mm), pipe and tube (OD 6-219 mm), wire (Ø0.10-12.0 mm) or a forged ring, disc or shaft from 5 kg to 3,000 kg.
  4. Step 4: Set the dimensions and tolerances. State the finished dimensions, condition (hot rolled, cold drawn, solution annealed, spring temper) and surface finish against the form’s stock range, so the mill certificate matches the drawing.
  5. Step 5: State the standard and certificate. Declare the governing ASTM / AMS / GB/T standard and the certification level: EN 10204 3.1 with heat-specific chemistry, or 3.2 third-party witnessed. The grade is proven by the mill test certificate, not assumed.

Frequently Asked Questions (FAQ)

How does superalloy density and weight resolve for 4J29?

One verified figure, 8.17 g/cm³, sits beneath the whole weight discussion for 4J29. Multiply 8.17 g/cm³ by the section volume and the quote’s mass line stops being a surprise.

What is 4J29 best used for?

4J29 is stocked for glass-to-metal and ceramic-to-metal seals in electronic packages; the documented edge is that the Kovar expansion alloy whose expansion matches borosilicate glass for hermetic seals.

What forms is 4J29 available in?

The stocked forms are Wire, Strip, Bar & Rod, Plate & Sheet; sizes follow the stock range for the form you pick.

What standards does 4J29 meet?

Every 4J29 order cites its governing standard (ASTM F15, GB/T 14986, MIL-I-23011) and arrives with an EN 10204 3.1 certificate proving the heat.

When does 4J29 stop being the right choice?

The ceiling is 450 °C and the family is fixed, so anything hotter or more aggressive calls for a different grade.